Performance Data

Electrocoagulation Lab Results:

 

Generator Rebuilding Facility

Contaminant
Raw
Treated
Removal Efficiency
Total Dissolved Solids
1,300 mg/L
620 mg/L
52.3%
Total Suspended Solids
36 mg/L
<5 mg/L
>86.1%
Oil & Grease
78 mg/L
2.7 mg/L
96.5%
TPH (Hydrocarbons)
30 mg/L
<1 mg/L
>96.6%
MBAS (Surfactants)
1.3 mg/L
0.062 mg/L
95.2%
Copper
4.1 mg/L
0.017 mg/L
99.5%
Lead
0.471 mg/L
<0.00375 mg/L
>99.29%
Nickel
0.013 mg/L
.005 mg/L
96.3%
Zinc
5.75 mg/L
0.084 mg/L
98.5%

 

Wood Preserving Facility

Contaminant
Raw
Treated
Removal Efficiency
Arsenic
0.120 mg/L
0.015 mg/L
87.5%
Chrome
0.326 mg/L
0.080 mg/L
76.8%
Hex Chrome
0.165 mg/L
0.039 mg/L
76.5%
Copper
0.308 mg/L
0.073 mg/L
76.2%

 

Metal Finishing

Contaminant
Raw
Treated
Removal Efficiency
TSS
22,700 mg/L
149 mg/L
99.3%
Zinc
12,800 mg/L
20.7 mg/L
99.8%
Copper
15.1 mg/L
0.03 mg/L
99.8%
Iron
197 mg/L
3.13 mg/L
98.4%
Lead
2.97 mg/L
0.0005   mg/L
99.9%

 

Shipyard Hull Wash Water

Contaminant
Raw
Treated
Removal Efficiency
Zinc
8.14 mg/L
0.107 mg/L
98.6%
Copper
6.78 mg/L
0.0661   mg/L
99%
Lead
0.151 mg/L
<0.001   mg/L
>99.3%
Nickel
0.0530   mg/L
0.00357   mg/L
93.2%

 

Marine Dry Dock Runoff

Contaminant
Raw
Treated
Removal Efficiency
TSS
1071 mg/L
23 mg/L
97.9%
Copper
170 mg/L
0.12 mg/L
99.9%
Zinc
151 mg/L
0.34 mg/L
99.8%

 

Metals Removal Performance Data (ND= Non-Detect)

 

Marine Stormwater Runoff

Contaminant
Before EC
After EC
Percent Removal
Copper
661 ppb
24.9 ppb
96.2%
Zinc
380 ppb
ND <2   ppb
>99.5%
TSS
16 ppm
ND <2   ppm
>87.5%
HEM Oil & Grease
ND <1.4
Not Tested
N/A

 

Wire Pulling (Manufacturing) Operation

Contaminant
Raw
Treated
Removal Efficiency
Copper 
0.549 mg/L
0.00525 mg/L
99%
Iron 
598 mg/L
<1 mg/L
>99.8%
Nickel
2.55 mg/L
0.0109 mg/L
99.5%
Zinc 
107 mg/L
0.00512  mg/L
99.9%

 

Galvanizing Operation

Contaminant
Raw
Treated
Removal Efficiency
Zinc 
32.9 mg/L
0.412  mg/L
98.7%

Share this article